SHIELD

Addressable Control Panel

Shield NEO Fire control panels provide a unique scalable platform that can expand upwards or downwards to suit virtually any application.
NEO is the result of decades of fire alarm and detection experience gained from installations across the globe, involving architects, engineers, consultants, end users and fire authorities.

  •  1, 2, or 4 SLC loop formats.
  • Each 500mA digital signaling line circuit supports up to 126 intelligent devices.
  • 1,000 Fire Zones when networked or 200 per panel.
  • Easy, high performance networking (up to 200 nodes).
    Status monitoring from any panel or annunciator.
  • True peer to peer networking Style 4 or 7, wire or fiber.
  • Individual node configurable event reporting and control.
  • Comprehensive network diagnostics.
  • Compatible with all of the NEO series peripherals including annunciators, relay modules, I/O modules, power supplies, internal and portable printers, network modules, LED/ switch modules, conventional zone module, modem, RS232, amplifiers, DACT and more.
  • SLC wiring can be shielded or non shielded.
  • Smoke detectors, sounder bases, open area sounders and beacons can be powered from SLC without need for a separate 24V supply.
  • Superb noise immunity and emissions.
  • Regulated loop voltage sustained during AC loss.
  • Panel includes large 240×60 backlit LED with simple navigation and programing.
  • Unique, built-in voltage and current meters for easy diagnostics can be viewed on panel or remotely.
  • Unique auto-test of battery cell integrity.
  • USB or RS232 interface for programming/panel monitoring.
  • Remote access and control via IP Gateway or Virtual Panel tools.
  • 100% digital communications on the SLC to all intelligent smoke detectors and I/O modules .
  • Fast response and superior rejection of unwanted RF noise.
  • Multi-sensor programming options allow for supervisory pre-alarm upon programmable smoke obscuration and fire alarm upon programmable temperature fixed or rate of rise.
  • Fully integrated 40/80 Watt digital audio options.
  • Shield’s simple select and click programming and configuration.
  • Autolearn and SLC loop detection.
  • Quick start and protect – a working system after an Autolearn is performed.

Smoke Detector

SHIELD Photo-Electric Smoke Detector works on the light-scatter principle and is ideal for applications where slow-burning or smoldering fires are likely.

  • Responds well to slow-burning, smoldering fires.
  • Well suited for bedrooms and escape routes.
  • Unaffected by atmospheric pressure

Technical Data

  • Detector Type: Photoelectric
  • Working Voltage: 17 – 28 V DC
  • Modulation Voltage: 5 – 9 V (V peak to peak)
  • Maximum Alarm Current LED On: 4.5 mA
  • Surge Current: 1.0 mA
  • Supervisory Current: 340 μA
  • Test Method: Home Safeguard, Gemini 501
  • Storage Temperature Range: -30°C to +80°C
  • Operating Temperature Range: -20°C to +60°C
  • Dimensions (diameter x height): 100 mm x 42 mm
  • Weight: 105 g

Multi Detector

SHIELD Multisensor contains a photo-electric smoke sensor and a thermistor (temperature sensor) whose outputs are combined to give the final analog value.

  • Sensitive to a wide range of fires.
  • Well suited for environments such as hotel bedrooms, warehouses & loading docks.
  • Unaffected by wind or atmospheric pressure.

Model S-A4014

Technical Data

  • Detector Type: Photoelectric Smoke Sensor and Thermistor
  • Working Voltage: 17 – 28 V DC
  • Modulation Voltage (V peak to peak) 5 – 9 V
  • Maximum Alarm Current LED On: 3.5 mA
  • Surge Current: 0 mA
  • Supervisory Current 500 µA
  • Test Method: Home Safeguard, Gemini 501
  • Dimensions (diameter x height): 100 mm x 50 mm
  • Weight: 105 g

Heat Detector

S-A4013

SHIELD Heat Detector is distinguishable by the low airflow resistant case and

  • uses a single thermistor to sense the air temperature around the detector.
  • Ideal for environments that are dirty or smoky under normal conditions.
  • Well suited for warehouses, loading docks and parking garages.
  • Unaffected by wind or atmospheric pressure.
  • Remote test feature

Technical Data

  • Detector Type: Heat
  • Working Voltage: 17 – 28 V DC
  • Modulation Voltage (V peak to peak): 5 – 9 V
  • Maximum Alarm Current LED On: 2.5 mA
  • Surge Current: 1.0 mA
  • Supervisory Current: 250 µA
  • Heat Element Rating: 135°F (57°C)
  • Test Method: Hair Dryer
  • Dimensions (diameter x height): 100 mm x 42 mm
  • Weight: 105 g

Sounder

The S-C8055 and S-C7055 Horns are audible signal appliances listed according to UL 464 (10th Edition) for indoor use. The temporal tone generated by the horn portion is designed as per ANSI and NFPA72 for standard emergency evacuation signaling requirement. The horn has the feature that can synchronize multiple horns in a complete fire alarm system.

Operating Voltage
Regulated 16 to 33 dc/fwr
RMS Operating Current (mA)
DC
35
FWR
47
Sound Level (dBA)
Voltage
16V
24V
33V
Reverberant
80
82
85
Anechoic
85
89
91
Directional Characteristics
Horizontal axis
Angle
OSPL (dBA)
0° (ref)
0 (ref)
+/- 44°
-3
+/-54°
-6
+/-90°
-10.5
Vertical Axis
Angle
OSPL (dBA)
0° (ref)
0° (ref)
+/-52°
-3
+/-55°
-6
+/-90°
-12
Operational Temperaure
0° C to 49° C
Operational Humdity
0 to 93% Rh
Horn Pattern
Temporal 3
Wire size
12 to 18 AWG
Location
Indoor wall/ceiling

Sounder with Flasher

The S-C8056 S-C7056 Horn Strobes and S-C8057/ S-C7057 Strobes are a family of multi-candela visual and audible signal appliances with light sources generated from white LED, listed according to UL 1638 and UL 464 (10th Edition) for indoor use. The LED light source offers superior performance, including low power consumption and long operating life. Six levels of light output are selectable. Figure 1 shows relative light outputs in horizontal and vertical dispersion from strobes mounted on walls/ceilings.

The strobe appliances produce a flash rate of one flash per second over the Regulated Voltage Range. The temporal tone generated by the horn portion is designed as per ANSI and NFPA72 for standard emergency evacuation signaling requirement.

The appliance has the feature that can synchronize multiple horn and/or strobes in a complete fire alarm system.

Operating Voltage
16 to 33 Vdc/fwr
RMS Operating Current @16 Vdc (mA)
130 cd
105 cd
85 cd
50 cd
35 cd
20 cd
S-C8056
S-C7056
164
126
85
55
47
30
S-C8057
S-C7057
156
119
80
49
43
28
RMS Operating Current @16V fwr (mA)
130 cd
105 cd
85 cd
50 cd
35 cd
20 cd
S-C8056
S-C7056
187
158
102
66
58
38
S-C8057
S-C7057
154
150
97
61
53
35
Sound Level (dBA)
Voltage
16vdc/fwr
24Vdc/fwr
33Vdc/fwr
UL Reverberant
77
81
85
ULC Anechoic
85
88
91
Directional Characteristics
Horizontal Axis
Angle
OSPL (dBA)
0° (ref)
0° (ref)
+/- 44°
-3
+/-54°
-6
+/-90°
-10.5
Vertical Axis
Angle
OSPL (dBA)
0° (ref)
0° (ref)
+/- 52°
-3
+/-55°
-6
+/-90°
-12
Effective Light (cd)
20,35,50,85,105,130
Operating Temperature
0° C to 49° C
Operating Humidity
0° C to 93% RH
Horn Pattern
Temporal 3
Strobe pattern
1flash per second
Wire size
12 to 18 AWG
Location
Indoor wall/ceiling

Beam Detector

The system comprises of a single unit incorporating an infrared transmitter and receiver. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analyzed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level is reached. The system is designed to be mounted so the beam will project between 0.5 m and 0.6 m below and parallel to the ceiling. Lateral detection may be up to 9.144m on either side of the beam, providing a maximum total coverage area of up to 19,800 square feet (18.29 m x 100 m).

  • Easy set up and alignment.
  • Single compact housing.
  • Calibrated obscuration test filter included.
  • Microprocessor controlled.
  • Alarm latching or auto reset.
  • Automatic gain control.
  • 12 V DC or 24 V DC operation.
  • Separate alarm and trouble contacts.
  • Remote Test Station available.

Technical Data

  • Primary Input Power: 10.2 to 30 V DC
  • Standby Current: 4 mA @ 24 V DC
  • Alarm Current: 15 mA @ 24 V DC
  • Relay Contacts: 1A at 30 V DC Resistive
  • Reset Time: 5 Seconds Maximum
  • Start Up Time: 10 Seconds
  • Optical Wavelength: 880 nm
  • Relative Humidity: 10% to 93% RH Non-condensing
  • Housing: Flame Retardant ABS
  • IP Rating: IP50
  • Finish: Grey/Black
  • Range: S-C1050 (5 m to 50 m) S-C1100 (50 m to 100 m)
  • Temperature Rating: -20°C to +55°C 0°C to +38°C
  • Sensitivity: 25%, 35%, 50%
  • Dimensions (L x W x D): 210 mm x 126 mm x 120 mm
  • Weight 0.67 Kg

Control/Output Module

SHIELD Switch Monitor Module is designed to monitor the state of one or more single pole, voltage free contacts connected and to report the status to SHIELD compatible analog control equipment.

  • Reports ‘trouble’, ‘switch open and ‘switch closed’ levels
  • Visible LED
  • Loop-powered
Style
Fascia plate with wiring terminals
Temperature range
32°F to 120°F
Wiring size
24 AWG - 14 AWG
Signal line circuit (SLC)
Supervised power limited
Working Voltage
5 - 9 V DC (peak to peak)
Operating Current
Supervisory Current : 8000 μA Surge Current : 7.5 mA Maximum Alarm Current: 6.0 mA (LED on)
Functional States
Analog Level (normal) : 16 Analog Level (alarm) : 64 Analog Level (trouble) : 4
Dimensions (L x W x D)
114 mm x 114 mm x 25 mm

Monitor/Input Module

Switch Monitor Module is designed to monitor the state of one or more single pole, voltage free contacts connected and to report the status to SHIELD compatible analog control equipment.

  • Three input states – ’normal’, ‘trouble’, and ’alarm’
  • Visible LED
  • Loop-powered
Style
Fascia plate with wiring terminals
Temperature range
32°F to 120°F
Wiring size
24 AWG - 14 AWG
Signal line circuit (SLC)
Supervised power limited
Working Voltage
17 - 28 V DC
Modulation Voltage
5 - 9 V DC (peak to peak)
Operating Current
Supervisory Current: 1.1 mA Surge Current: 2.5 mA Maximum Alarm Current: 5 mA (LED on)
Functional States
Analog Level (normal): 16 Analog Level (alarm): 64 Analog Level (trouble): 4
Dimensions (L x W x D) 1
114 mm x 114 mm x 25 mm

Sounder Base

SHIELD Sounder Beacon Base is a loop powered sounder and beacon combined with a standard intelligent Mounting Base. It used to signal a fire alarm in enclosed areas. The Sounder Beacon Base can be used either with a detector fitted or with a cap for operation as a stand-alone alarm device.

Operating voltage
17 - 28 V DC
Sounder Output
High Volume Setting
Nominally 66.8-77.6db (A) at 10 Ft.
Low Volume Setting
Nominally 52.5-66.7db (A) at 10 Ft.
Current Consumption at 24VDC (with Protocol Polling)
Normal Standby
< 900 μA
Switch - on Surge
1.2 mA for 1 sec.
Sounder/Beacon Operating
8.75 mA
IP Rating
IP21C
Temperature Range
-10°C to +60°C
Humidity Range
0 - 95 %