Foam & Gas Suppression System

Foam Suppression System

Fire suppression foam is a powerful firefighting agent made by combining foam concentrate, water, and air. When properly mixed, it forms a thick, cohesive blanket that smothers flames by:

  • Coolingthe fire.
  • Blockingoxygen from the fuel source.
  • Suppressingflammable vapors.
  • Creating a barrierbetween the fire and the fuel.

This makes foam suppression systems ideal for controlling fires involving flammable liquids

NAFFCO’s Pre-Piped Vertical Bladder Tank System

A compact, self-contained solution for automatic foam proportioning, the NAFFCO Pre-Piped Vertical Bladder Tank integrates a bladder tank, ratio controller, and pre-assembled piping. It ensures precise foam concentrate injection into water streams—without external power.

Key Features & Operation

  • Bladder Tank Design:Water pressure compresses the bladder, pushing foam concentrate into the system.
  • Automatic Proportioning:As water flows through the ratio controller, it creates a vacuum effect, drawing foam concentrate at the correct ratio.
  • Wide Flow Range:Maintains consistent performance across varying pressures and flow rates.

This system guarantees reliable, energy-free foam mixing for effective fire protection in high-risk environments.

Tank Shell
Carbon Steel, SA 516 Gr.70.
Bladder
Vinyl Based Polymer
Pressure Relief Valve (Optional)
Brass Construction with Set Pressure @ 15 bar
Internal Piping
Perforated PVC, sch. 80,
Flanges
ASTM A105, Class 150
Water Pipe
Carbon Steel. sch. 40.
Foam Pipes
Stainless Steel. sch. 40.
Vent/Drain/NRV Valves
Sight Gauge with Shut Off & Drain Valve
Painting External
Zinc Rich Primer with Red Enamel Finish
Painting Internal
Zinc Rich Primer with Coal Tar Epoxy Paint

Powder Based EXT

Our pre-engineered dry chemical system rapidly smothers flames with a fine powder layer. The cartridge-operated system features:

  • Automatic fire detection
  • Manual/auto activation
  • Fixed nozzles or hose-line distribution

When triggered, high-pressure gas fluidizes the powder, ruptures the safety disc, and propels extinguishing agent through the network. Fixed nozzles deliver targeted suppression, while manual hose lines allow operator control. Ideal for industrial hazards, this system provides instant fire knockdown by cutting off oxygen and inhibiting chemical reactions. The robust design ensures reliable performance in high-risk environments like machinery spaces, chemical plants, and energy facilities.

NAFFCO provides advanced fire suppression systems for industrial hazards and mobile equipment, offering both local application and total flooding solutions. Our systems include dry chemical (powder) extinguishing options for versatile protection. Key components consist of dry chemical storage tanks, expellant gas cartridges, distribution hoses with nozzles, and manual/automatic activation with detection systems. These robust, configurable solutions deliver rapid, reliable fire suppression for high-risk environments. Ideal for oil & gas, manufacturing, and heavy machinery applications, NAFFCO’s systems ensure optimal safety through precision engineering and adaptable design for spot or full-area coverage. Trusted globally for performance and durability.

Wet Chemical Fire Suppression

Commercial kitchens face extreme fire risks from open flames, hot surfaces, and grease buildup, making them prone to fast-spreading, hard-to-control fires. NAFFCO’s Kitchen Mister System tackles this danger with advanced misting technology, delivering rapid suppression for oil and grease fires before they escalate. As the most effective fixed kitchen fire protection solution available, it quickly extinguishes flames, minimizing damage and downtime. Trusted by fire safety professionals worldwide, the Kitchen Mister System sets the standard for commercial kitchen safety, combining cutting-edge design with reliable performance to protect high-risk cooking environments from devastating fires.

SYSTEM CYLINDERS

The models NF-KS5, NF-KS10, NF-KS15, and NFKS20 cylinders are designated by flow point capacity (so the NF-KS5 supports five (5) flow points) instead of the amount of agent they hold. Recharge is available in 5 and 10 flow point containers, so there’s never a chance of error.

DISCHARGE NOZZLES

All five (5) Kitchen Mister nozzles come equipped with a color identification band: red, blue, green, white, and yellow. This allows for easy identification of the nozzle even when it’s installed in difficult locations, such as a duct or plenum area. The nozzle is also stamped with its model number.

FM 200

As the leading Halon 1301 alternative, FM-200™ has become the global standard for waterless fire suppression, with over 100,000 installations across 70+ countries. This advanced system extinguishes fires in under 10 seconds without residue, protecting sensitive equipment and high-value assets while being safe for occupied spaces.

FM-200™ (HFC-227ea) is an environmentally friendly compound composed of carbon, fluorine, and hydrogen. It works primarily through heat absorption, with additional flame-inhibiting chemical action. Approved by the EPA under its SNAP program, FM-200™ meets NFPA 2001 standards and carries UL/FM certifications, with marine variants available for USCG/ABS compliance.

Ideal for data centers, telecom facilities, and industrial applications, FM-200™ is non-corrosive to metals, plastics, and electronics. Its zero ozone-depleting properties and rapid discharge capability make it the preferred choice for critical infrastructure protection worldwide.

PHYSICAL PROPERTIES

Chemical Name
Heptafluoropropane (CF3CHFCF3)
Molecular Weight
170.03
Boiling Point @ 760 mm Hg
3.9°F (-15.6°C)
Freezing Point
-204°F (-131.1°C)
Critical Temperature
215°F (101.7°C)
Critical Pressure (psia)
422 psia (2912 kPa)
Critical Volume (ft3/lbm) (cc/mole)
0.0258 (274)
Critical Density (lbm/ft3)
38.8 (621 kg/m3)
Specific Heat, Liquid (BTU/lb-F°) @ 77°F (25°C)
0.283 (1.184 kj/kg/°C)
Specific Heat, Vapor (BTU/lb-°F) @ constant pressure of 1 ATM @ 77 F (25 c)
0.1932 (0.808 kj/kg/°C)
Heat of Vaporization (BTU/lb) at Boiling Point
57.0 (132.6 kj/kg)
Thermal Conductivity (BTU/h ft°F) of Liquid @ 77°F (25°C)
0.040 (0.069 w/m°C)
Viscosity, Liquid (lb/ft/hr) @ 77°F (24°C)
0.443 (0.184 centipoise)
Vapor Pressure (psia) @ 77°F (25°C)
66.4 (457.7 kPa)
Ozone Depletion Potential
0
Estimated Atmospheric Lifetime (years)
31 - 41
LC50 (Rats; 4hrs - ppm)
>788,000

NOVEC 1230

The Advanced, Eco-Friendly Alternative to Halon 1301

Novec 1230 fluid represents the next evolution in clean fire suppression technology. Engineered for safety, performance, and environmental responsibility, it delivers rapid fire extinguishing without compromising air quality or human health.

Key Benefits:

✔ Human-Safe – Approved for use in occupied spaces.
✔ Planet-Friendly – Atmospheric lifetime of <5 days, ensuring negligible Global Warming Potential (GWP).
✔ Zero Ozone Impact – Ozone Depletion Potential (ODP) of 0.
✔ EPA-Approved – Recognized under the SNAP Program for sustainable alternatives.
✔ Ultra-Fast Suppression – Discharges in 10 seconds or less, protecting critical assets from fire damage.
✔ Compliant & Certified – Meets NFPA 2001 standards, with UL Listing, FM Approval, and optional USCG/ABS Marine Certifications.

How Does Novec 1230 Work?

Novec 1230 fluid (chemical formula: CF₃CF₂C(O)CF(CF₃)₂) extinguishes fires primarily through heat absorption, with an additional chemical reaction from thermal decomposition in flames.

  • Non-conductive & residue-free– Ideal for sensitive electronics and high-value equipment.
  • Sustainable & efficient– Developed by 3M for maximum performance with minimal environmental impact.

Shield Novec 1230 Clean Agent Fire Suppression Systems are highly efficient when combined with a properly designed plumbing network using the Shield version of the VDS Flow Calculation Software.

COMPONENTS

  • Cylinders: cylinders are manufactured in accordance with DOT 4BW500 and TC BWM34* standards. *490L cylinder assemblies are only DOT T4BW500 compliant.
  • Valve Assembly: All valves are of the pressure differential design, and will not operate without deliberate actuation. The actuation devices can be removed while under pressure to facilitate functionality testing of the system. It is also equipped with a monitoring Pressure Switch as well as a port to facilitate pneumatic actuation of secondary cylinder assemblies.
  • Cylinder Straps: The cylinder body straps are designed to secure the system assembly during discharge. A single strap is included with all systems up to 103L, while larger systems are equipped with two straps. Systems 490L in size are shipped with two wall mount straps, floor mount straps are available upon request.

INERT Gas

NAFFCOInert® fire suppression system is an engineered system using with fixed nozzle agent and pipe network. NAFFCOInert® systems are designed in accordance with latest edition of NFPA 2001,”Standard on clean agent systems”. This system shall be designed for Class A, Class B & Class C application; it extinguishes fire by reducing residual oxygen concentration to a level that will no longer support combustion. The system can actuate by detection and control equipment for automatic operation along with providing local manual operation when needed.

Basic Uses: NAFFCOInert® fire suppression system is particularly useful for suppressing fires in hazard areas where an electrically non conductive medium is essential or desirable. Where the clean environment and the hazard obstructions require the use of a gaseous agent. It is an ideal replacement agent for Halon 1301 alternative.

  • Telecommunication facilities
  • Electrical and Electronics hazard areas
  • Data Centers
  • Control Rooms
  • Museums / Archives
  • Military Installations
  • Libraries
  • Medical facilities

PRESSURE REGULATOR TECHNOLOGY

Pressure Regulators modulate the discharge pressure to a constant 40-60 Bar which still delivers the design concentration within 60 seconds, but with significant performance and cost benefits:

BETTER SAFETY

  • Prevents discharge freeze-up
  • Prevents explosive force of discharge

SAVES TIME AND MONEY

  • Enables low pressure manifolds & pipework to be used that are of lower cost and easy to install
  • Reduces the difficulty and cost of locating/fitting pressure vents in the protected space

EASY MAINTENANCE

  • After a system discharge, simply remove the regulator, recharge, and reconnect. No reconditioning necessary
  • Functional tests are possible even while the SYSTEM IS ARMED

PHYSICAL PROPERTIES OF IG-01

Chemical Name
Ar (Argon)
Molecular Weight
39.9
Boiling Point at 1.013 Bar
-185.9°C
Critical Pressure
49 Bar
Critical Temperature
-122.3°C
Design Concentration for Class A Fire (NFPA)
38.7%
Design Concentration for Class A Fire (NFPA)
38.7%
Flooding Factor for Class A Fire (NFPA)
0.481 m³/ m³
NOAEL
43%
LOAEL
53%

PHYSICAL PROPERTIES OF IG – 100.

Chemical Name
N² (Nitrogen)
Molecular Weight
28
Boiling Point at 1 ATM (1.013 Bar)
-196°C
Critical Pressure
40 Bar
Critical Temperature
-146.9°C
Design Concentration for Class A Fire (NFPA)
37.2%
Flooding Factor for Class A Fire (NFPA)
0.457 m³/ m³
NOAEL
43%
LOAEL
53%

PHYSICAL PROPERTIES OF IG – 55

Chemical Name
N²/Ar
Molecular Weight
33.95
Boiling Point at 760 mm Hg
-190.1ºC
Critical Pressure
602 psia
Critical Temperature
-134.7ºC
Design Concentration for Class A Fire (NFPA)
37.2%
Flooding Factor for Class A Fire (NFPA)
0.457 m³/ m³
NOAEL
43%
LOAEL
53%

PHYSICAL PROPERTIES OF IG – 541

Chemical Name
N²/Ar/CO²
Molecular Weight
34
Boiling Point at 1 ATM (1.013 Bar)
-196ºC
Critical Pressure
N/A
Critical Temperature
N/A
Design Concentration for Class A Fire (NFPA)
37.2%
Flooding Factor for Class A Fire (NFPA)
0.457 m³/ m³
NOAEL
43%
LOAEL
52%